| Leica SP5 II | Inverted | ✔ | DIC | ✔ | | LeicaASF | Lasers: 405, 456, 476, 488, 496, 514, 561, 633nm | B2|03 | 158 | FB10 | Alexander Rapp 2380/Tobias Meckel 3503 | http:\\130.83.98.149 |
| Leica Confocal | inverted | ✔ | DIC | | | Leica spectral Detector | confocal scanning microscope, 488 nm, 534nm, 633 nm | B2|03 | 158 |FB10 | Tobias Meckel 3503/ Alexander Rapp 2380 | http:\\130.83.98.149 |
| Nikon Ti-E | inverted | ✔ | DIC | ✔ | ✔ | Volocity 5.4 | Confocal Spinning Disk with FRAP unit, Laser: 405, 488, 561, 640 nm | B2|03 | 232 |AG Cardoso | Alexander Rapp 2380 | |
| Axioskop Zeiss | upright | ✔ | | | | AxioCam mrm + AxioVision | manual, Filters: DAPI, FITC, Rhodamine | B2|03 | 3 |AG Goeringer | Ulrich Gringer 2855 | |
| Zeiss Axiovert 200 | inverted | ✔ | Phase | | | SensiCam +AxioVision | automated, manual stage, Filters: DAPI, CFP, GFP, mRFP, Cy5 | B2|03 | 232 | AG Cardoso | Alexander Rapp 2380 | |
| Zeiss AxioPlan 2 | upright | ✔ | Phase | | | SensiCam + AxioVision | widefield imaging, multiple filters, SensiCam Axiovision | B2|03 | 232 | AG Cardoso | Alexander Rapp 2380 | |
| Zeiss Axioskop | upright | ✔ | | | | | manual | B2|06 | 110a |AG Loebrich | Eik Schumann 7463 | |
| Zeiss Axiovert | inverted | ✔ | Phase | ✔ | ✔ | Jai_Metafer
| Software Metafer (Metasystems), mit Inkubationskammer fr Life Cell Imaging
| B2|06 | 110a |AG Loebrich | Eik Schumann 7463 | |
| Zeiss Observer | inverted | ✔ | Phase | ✔ | | | Manual | B2|06 | 110a |AG Loebrich
| Eik Schumann 7463 | |
| Zeiss Axiovert | inverted | ✔ | Phase | ✔ | ✔ | AxioCam mrm _ AxioVision | automatisiert, Software Metafer; Metacyte; Isis (Metasystems); Axiovision (Zeiss) | B2|06 | 110a |AG Loebrich | Eik Schumann 7463 | |
| Zeiss Axioplan 2 | upright | ✔ | | ✔ | | AxioCam mrm _ AxioVision | automatisiert, Software Metafer;Metacyte, Msearch; Isis (Metasystems) | B2|06 | 110a |AG Loebrich | Eik Schumann 7463 | |
| Nikon Ti-E C1-si confocal | inverted | ✔ | | ✔ | | EZ-C1-si + Huygens + Andor EMCCD + NIS-Ar | Confocal, AOTF, TIRF, FLIM, Spectral imaging, Lasers 405 ( cw/pulsed), 488, 543, 633nm, Fluor.Filters YoYo, TRITC, Cy5, Tripleband FITC/Cy3/Cy5, Q-Dot-LP | CSI TU Darmstadt | Natalya Pertaya 6610 | pertaya@csi.tu-... |
| Reichert | | | Phase | | | | Optional digital Camera | B1|01 |178 |AG Thiel | Tobias Meckel 3503 | |
| stereo | | | | | Olympus C-7070 | | B1|01 |178 |AG Thiel | Tobias Meckel 3503 | |
| Fluorescence Microscope | upright | ✔ | | | | Andor Luca | | B1|01 |178 |AG Thiel | Tobias Meckel 3503 | |
| Zeiss | upright | | DIC | | | Powershot A 630 | | B1|01 |178 |AG Thiel | Tobias Meckel 3503 | |
| TIRF Microscope | inverted | ✔ | | | | | single molecule sensitivity | B1|01 |178 |AG Thiel | Tobias Meckel 3503 | |
| Zeiss Axiophot | upright | ✔ | | | | | | B2|06 | 9 | AG Layer | Florian Frohns 6105 | |
| Zeiss Observer D1 | inverted | ✔ | | | | | | B2|06 | 9 | AG Layer | Florian Frohns 6105 | |
| Zeiss, Axioplan 2 | upright | ✔ | Phase | ✔ | | CoolCube_Metafer | automatisiert, Software Metafer; Metacyte (Metasystems) | B2|06 | 110a |AG Loebrich | Eik Schumann 7463 | |
| 13x Axio Vert A1 | Inverted | ✔ | Phase 1 | | | Zen Light Multi Channel &bw camera AxioCam ICm 1 | LED Fluorescence Light DAPI, FITC, Rhod, Cy5 | B2|03 | Alexander Rapp | ttp:\\130.83.98.149 |